Availability: | |
---|---|
Quantity: | |
BLS-1A
BLS
Applicable standards: GB6238, GB11146, GB11133 and more than 20 national standards
Application Areas
Pharmaceutical, organic chemical, inorganic chemical, petrochemical, fertilizer, pesticide, dye, coating, food and beverage, surfactant and cosmetics, etc.
Features
1. The entire liquid circuit is made of special materials, with excellent corrosion resistance, which can ensure long-term continuous work;
2. Adopt the electrode polarization voltage to judge and display the end of the reaction, and terminate the titration;
3. Fully enclosed system to avoid the infiltration of environmental moisture;
4. Adopt common test (solvent) bottle cap as joint, easy to replace;
Functions
5. Press the relevant function keys, the instrument can achieve: solvent inhalation, determination, end point display (alarm), waste liquid discharge, stirring;
6.Adopt special reagent bottle joint, which can use standard pyridine or pyridine-free reagents;
7. Adopts high-brightness digital tube, clear display;
8. Once the operation is wrong, it can be immediately interrupted and re-operated;
9. Adopt the pipeline system with totally enclosed design to avoid the escape of toxic gas, protect the environment and health. The instrument runs smoothly without noise
Technical Parameters
1. Measuring range: 30ppm-100% (H2O mass fraction)
2. Resolution: 0.01ml
3. Burette capacity: ≥25ml
4. Sensitivity: 10-6A
Applicable standards: GB6238, GB11146, GB11133 and more than 20 national standards
Application Areas
Pharmaceutical, organic chemical, inorganic chemical, petrochemical, fertilizer, pesticide, dye, coating, food and beverage, surfactant and cosmetics, etc.
Features
1. The entire liquid circuit is made of special materials, with excellent corrosion resistance, which can ensure long-term continuous work;
2. Adopt the electrode polarization voltage to judge and display the end of the reaction, and terminate the titration;
3. Fully enclosed system to avoid the infiltration of environmental moisture;
4. Adopt common test (solvent) bottle cap as joint, easy to replace;
Functions
5. Press the relevant function keys, the instrument can achieve: solvent inhalation, determination, end point display (alarm), waste liquid discharge, stirring;
6.Adopt special reagent bottle joint, which can use standard pyridine or pyridine-free reagents;
7. Adopts high-brightness digital tube, clear display;
8. Once the operation is wrong, it can be immediately interrupted and re-operated;
9. Adopt the pipeline system with totally enclosed design to avoid the escape of toxic gas, protect the environment and health. The instrument runs smoothly without noise
Technical Parameters
1. Measuring range: 30ppm-100% (H2O mass fraction)
2. Resolution: 0.01ml
3. Burette capacity: ≥25ml
4. Sensitivity: 10-6A