BLS-1384
BLS
90278990
I.Application
The BLS-1384 engine coolant corrosion tester is designed and manufactured according to ASTM D1384 and national SH/T0085 Testing Method for Engine Coolant Corrosion,suitable to measure the corrosion degree of high-boiling and low-boiling engine coolants and their concentrates on typical metal test pieces. The equipment is upgraded with its own silent air compressor, no need to manually equip the gas source.
II.Technical Specifications
1. Power supply: AC220V±10%, 50Hz.
2. Beaker: made of heat-resistant glass. 1000ml high type without mouth, in line with the requirements of SH/T0085 standard.
3. Gas diffusion tube: The diffusion head is made of sand core glass, and the pipe diameter is made of heat-resistant glass.
4. Reflux condenser: water-cooled, the length of the sleeve is not less than 400mm.
5. Temperature control range: room temperature~+100ºC,accuracy: ±0.1ºC
6. Air flow meter: The flow range is 30~300ml/min
7.Timer timing range 0~9999 h
8. Ambient temperature: -10ºC~+35ºC.
9. Relative humidity: ≤85%.
10. Total power consumption: ≤2000W.
11.Dimension:430×420×450mm
12.Weight:28kg
13.Test piece size and material
50x20x2mm(20#steel,brass piece, red copper piece)
50x25x3.5mm(Cast aluminum piece, solder piece, cast iron piece)
Single center hole:φ7.0mm
I.Application
The BLS-1384 engine coolant corrosion tester is designed and manufactured according to ASTM D1384 and national SH/T0085 Testing Method for Engine Coolant Corrosion,suitable to measure the corrosion degree of high-boiling and low-boiling engine coolants and their concentrates on typical metal test pieces. The equipment is upgraded with its own silent air compressor, no need to manually equip the gas source.
II.Technical Specifications
1. Power supply: AC220V±10%, 50Hz.
2. Beaker: made of heat-resistant glass. 1000ml high type without mouth, in line with the requirements of SH/T0085 standard.
3. Gas diffusion tube: The diffusion head is made of sand core glass, and the pipe diameter is made of heat-resistant glass.
4. Reflux condenser: water-cooled, the length of the sleeve is not less than 400mm.
5. Temperature control range: room temperature~+100ºC,accuracy: ±0.1ºC
6. Air flow meter: The flow range is 30~300ml/min
7.Timer timing range 0~9999 h
8. Ambient temperature: -10ºC~+35ºC.
9. Relative humidity: ≤85%.
10. Total power consumption: ≤2000W.
11.Dimension:430×420×450mm
12.Weight:28kg
13.Test piece size and material
50x20x2mm(20#steel,brass piece, red copper piece)
50x25x3.5mm(Cast aluminum piece, solder piece, cast iron piece)
Single center hole:φ7.0mm