loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Tag Closed Cup Flash Point Tester BLS-56

Availability:
Quantity:
  • BLS-56

  • BLS

I. Application

The automatic closed flash point tester (Tiger's closed cup method) was designed and produced according to national standard GB/T 21929 "Tiger Closing Cup Flash Dot Measurement Method" and the automatic test method of ASTM D56.It is suitable for the flash point with liquid viscosity less than 5.5cst at 40 ℃ or less than 9.5cst at 25 ℃.

II.Features

1. The instrument is controlled by high -definition 7 -inch high -resolution liquid crystal touch display and touch screen button control.

2.All English human -machine operation interface, English words show, the experiment is automated control, intuitive operation.

3. The instrument has the full automation function of testing arm automatic lifting, automatic cooling/heating control, automatic ignition, automatic flash point detection and test results saving printing, and test ending automation.

4. Electronic silicon carbon stick ignition technology, electronic flames, no need to connect to gas, energy saving and environmental protection, and ensure the safety of the laboratory.

5.The instrument uses a high -precision A -class PT100 temperature sensor to detect the temperature.

6.When the sample reaches the preset temperature, automatically start ignition and automatically start to detect the flash point of the sample.

7.The instrument uses a high -precision flash point detector to detect the flash point, with a short response time and high sensitivity.

8.The digital module automatically detects the atmospheric pressure, and the test result automatically compensates to the correction value.

9.The instrument is equipped with a self -diagnostic system and reminder function; multiple experimental results can be stored.

10. Have time, date, and week setting function.

11.Have the function of heating up, and to limit the testing instrument to automatically stop the test and prompt.

12.The test ending the experiment number, result, and automatic printing.

III.Technical Parameters

1. Work voltage: AC220V ± 10%, 50Hz

2. Flash point test range: 5-93 ° C (the instrument can reduce the temperature of the sample to -5 ° C)

3. Heating rate: flash point <60 ° C (0.9 ~ 1.1 ° C/min); flash point ≥60 ℃ (2.7 ~ 3.3 ℃/min)

4. Detection interval: flash point <60 ℃ (0.5 ℃); flash point ≥60 ℃ (1 ℃)

5. Device maximum power: not greater than 300W (work when each component is different)

6. Heating power: 150W; cooling power: 160W; ignition stick power: 120W

7. Operation interface: 7 -inch high -resolution LCD touch screen, resolution 800*480.

8. Temperature display accuracy: 0.1 ℃

9. Per pressure detection: Digital pressure sensing chip, error ± 0.3kpa @25 ℃.

10. Refrigeration parts: semiconductor refrigeration film, with water flow switch protection function.

11. Refrigeration and heat exchange method: Cooling water cooling, randomly equipped with a submersible pump

12. Printer: Embedded thermist micro printer

13. Historical records: It can store 256 groups of historical results values

14. Hardware test: with switching cup lid test, ignition mechanism test, stirring test, ignition stick test, heating test, refrigeration test


Previous: 
Next: 

If you have any questions, please contact us via email or telephone and we will get back to you as soon as possible.

Contact Us

Copyright © 2023 Chongqing Blossom Machinery Equipment Co., Ltd  All Rights Reserved.  Technology by leadong.com