Availability: | |
---|---|
Quantity: | |
XF-120G
Application
The electronic liquid hydrometer uses the Archimedean volume displacement method to directly read the density of chemical solutions, additives, suspensions, emulsions, dispersions, isomorphous solutions, mouthwashes, medicines, and other high-viscosity, suspensions, emulsions, colloidal liquids, fluxes, colloids, oily bodies, and crude oils. It contains a standard RS-232 computer interface and can be easily connected to a printer.
It is mainly used in scientific research institutions, research laboratories, quality inspection institutes, chemical solutions, modern energy, petroleum fuels, fine chemicals, chemical reagents, chemical research laboratories, hospitals, blood banks, medical research laboratories... and other institutions or industrial fields. Suitable for density research, analysis and other fields.
The electronic liquid hydrometer uses an electromagnetic force sensor imported from Switzerland, with high precision and high stability. It can instantly display the density value. It is accurate in measurement, durable, stable in performance, powerful in function, simple in operation, beautiful in design, fine in workmanship, and only needs two measurement steps to display the density value.
Principle: According to GB/T611-2006, GB/T11540-2008, GB1666-81, GB/T5009.2-2003, GB/T 5526-1985, JJG171-2004, GB/T13531, T5526, T5009, GB/T11540, GB/T12206, GB/T5518 specifications. Use Archimedes volume displacement method to quickly read the liquid density.
Features
1. Can test the density of various liquids: high viscosity, suspension, emulsion, colloid, corrosive liquid
2. Simple measurement method, easy to clean, no cumbersome debugging and operation of Wei's balance method and specific gravity bottle method
3. Convenient sampling, only 50ml sample is needed for testing, the measuring cup is easy to clean, not limited by the small diameter of the specific gravity bottle, and can be reused. Disposable measuring cups can also be used
4. Has the function of testing corrosive liquids (optional special accessories)
5. Display density value in two operation steps
6. Fully automatic zero tracking function
7. Equipped with a special windproof and dustproof cover
9. Contains RS-232C communication interface, convenient for connecting PC and printer, optional XF-68 printer to print measurement data
Measurement steps:
1 Hang the standard weight on the weighing pan to weigh the weight, press the CAL key to store after stabilization
3. Put the weight connected to the hook into the liquid to be measured, press the CAL key to store after stabilization, and display the density value.
Standard accessories: ① Main unit, ② Density measurement frame, ③ YT-68 standard liquid measurement component, ④ 100G weight, ⑤ Power transformer ⑥ Windproof and dustproof cover
※ YT-68 standard liquid measurement component: including 1 stainless steel hook, 1 standard glass weight, 1 beaker
Technical Parameters
Model | XF-120G | XF-220G |
Density accuracy | 0.0001 g/cm3 | 0.0001 g/cm3 |
Density measurement range | 0.0001-7.8000g/cm3
| |
Maximum weighing | 120g | 220g |
Minimum weighing | 0.0001g | 0.0001g |
Setting | specific gravity hammer volume setting | |
Measurement type | liquid density greater than one or less than one | |
Calibration method | 100g single-button automatic calibration, distilled water verification result value | |
Output method | RS-232C standard communication interface, convenient test data output and printing. |
Application
The electronic liquid hydrometer uses the Archimedean volume displacement method to directly read the density of chemical solutions, additives, suspensions, emulsions, dispersions, isomorphous solutions, mouthwashes, medicines, and other high-viscosity, suspensions, emulsions, colloidal liquids, fluxes, colloids, oily bodies, and crude oils. It contains a standard RS-232 computer interface and can be easily connected to a printer.
It is mainly used in scientific research institutions, research laboratories, quality inspection institutes, chemical solutions, modern energy, petroleum fuels, fine chemicals, chemical reagents, chemical research laboratories, hospitals, blood banks, medical research laboratories... and other institutions or industrial fields. Suitable for density research, analysis and other fields.
The electronic liquid hydrometer uses an electromagnetic force sensor imported from Switzerland, with high precision and high stability. It can instantly display the density value. It is accurate in measurement, durable, stable in performance, powerful in function, simple in operation, beautiful in design, fine in workmanship, and only needs two measurement steps to display the density value.
Principle: According to GB/T611-2006, GB/T11540-2008, GB1666-81, GB/T5009.2-2003, GB/T 5526-1985, JJG171-2004, GB/T13531, T5526, T5009, GB/T11540, GB/T12206, GB/T5518 specifications. Use Archimedes volume displacement method to quickly read the liquid density.
Features
1. Can test the density of various liquids: high viscosity, suspension, emulsion, colloid, corrosive liquid
2. Simple measurement method, easy to clean, no cumbersome debugging and operation of Wei's balance method and specific gravity bottle method
3. Convenient sampling, only 50ml sample is needed for testing, the measuring cup is easy to clean, not limited by the small diameter of the specific gravity bottle, and can be reused. Disposable measuring cups can also be used
4. Has the function of testing corrosive liquids (optional special accessories)
5. Display density value in two operation steps
6. Fully automatic zero tracking function
7. Equipped with a special windproof and dustproof cover
9. Contains RS-232C communication interface, convenient for connecting PC and printer, optional XF-68 printer to print measurement data
Measurement steps:
1 Hang the standard weight on the weighing pan to weigh the weight, press the CAL key to store after stabilization
3. Put the weight connected to the hook into the liquid to be measured, press the CAL key to store after stabilization, and display the density value.
Standard accessories: ① Main unit, ② Density measurement frame, ③ YT-68 standard liquid measurement component, ④ 100G weight, ⑤ Power transformer ⑥ Windproof and dustproof cover
※ YT-68 standard liquid measurement component: including 1 stainless steel hook, 1 standard glass weight, 1 beaker
Technical Parameters
Model | XF-120G | XF-220G |
Density accuracy | 0.0001 g/cm3 | 0.0001 g/cm3 |
Density measurement range | 0.0001-7.8000g/cm3
| |
Maximum weighing | 120g | 220g |
Minimum weighing | 0.0001g | 0.0001g |
Setting | specific gravity hammer volume setting | |
Measurement type | liquid density greater than one or less than one | |
Calibration method | 100g single-button automatic calibration, distilled water verification result value | |
Output method | RS-232C standard communication interface, convenient test data output and printing. |